Indoor Air Quality in Steel Rolling Industries and Possible Health Effects DOI: 10.32526/ennrj.17.4.2019.28

Main Article Content

Kamel K. Al-Zboon
Osric Tening Forton

Abstract

Indoor air quality has significant impacts on occupational health, workers' comfort and their productivity.  The aim of this study was to assess indoor air quality in a rolling steel plant and to identify corrective measures that could help improve indoor air quality. Many air quality indicators, namely: CO, CO2, VOCs, NOx, SO2, O3, PM10 and PM2.5 were assessed as part of the study. The results obtained showed that higher concentrations of CO, VOCs, were found at the furnace area, while the rolling and quenching process area has the higher concentration of SO2 and CO2 respectively. PM10 and PM2.5 exceeded the international standards in most of the measuring points. Potential negative health effects are expected due to the high temperature and VOCs at the furnace area in addition to the high particulate matters level in all points. Hazard indices (HI) were found to be >1 for all sites indicating possible health risk mainly due to the particulate matter. The respiratory system is the most affected organ, followed by cardiovascular system, then the eye irritation. Based on the potential health risks identified, the paper concludes with some recommendations for protecting workers' health. These include setting local standards for indoor air quality, applying job rotation strategy, periodical medical checks, good ventilation and conducting further studies concerning long-term effect of indoor air quality on occupational health.

Article Details

How to Cite
K. Al-Zboon, K., & Tening Forton, O. (2019). Indoor Air Quality in Steel Rolling Industries and Possible Health Effects: DOI: 10.32526/ennrj.17.4.2019.28. Environment and Natural Resources Journal, 17(4), 20–29. Retrieved from https://ph02.tci-thaijo.org/index.php/ennrj/article/view/194435
Section
Original Research Articles

References

1. Al-Zboon K, Forton O. Indoor air quality in steel making industries. Environmental Management and Sustainable Development 2019;8(1):147-79.

2. AWH Solicitors. What are the occupational risks of working in the steel industry [Internet]. 2018 [cited 2018 September 18]. Available from: https://awhsolicitors.co. uk/ articles/industrial-disease/occupational- risks- steel-industry.

3. Carbon Capture and Storage Institute (CCS). General hazards associated with CO2 [Internet]. 2018 [cited 2018 July 25]. Available from: https://hub.globalcc sinstitute.com/ publications/ hazard - analysis - offshore-carbon - capture - platforms - and - offshore - pipelines /32-general-hazards-associated-co2.

4. Chan E, Riley M, Thomson M, Evenson E. Nitrogen oxides (NOx) formation and control in an electric arc furnace (EAF): Analysis with measurements and computational fluid dynamics (CFD) modeling. ISIJ International 2004;44(2):429-38.

5. Department of the Environment and Energy Australia (DOEE). Sulphur dioxide [Internet]. 2005 [cited 2018 July 22]. Available from: https://www.environment.gov .au/protection/publications/factsheet-sulfur-dioxide-so2.

6. Darus F, Zain-Ahmed A, Latifc M. Preliminary assessment of indoor air quality in terrace houses. Health and the Environment Journal 2011;2(2):8-14.

7. Echterhof T, Pfeifer H. Measurement and control of NOx emissions at two AC electric arc furnaces. ISIJ International 2011;51(10):1631-6.

8. European Environmental Agency (EEA). Air Pollutant Emission Inventory Guidebook 2016. Luxembourg: Publications Office of the European Union; 2016.

9. Environmental Protection Agency (EPA). National ambient air quality standards [Internet]. 1990 [cited 2018 September 21]. Available from: https://www.epa.gov/ criteria-air-pollutants/naaqs-table.

10. United States Environmental Protection Agency (U.S. EPA). Air Quality index: A Guide to Air Quality and Your Health. North Carolina, USA: Environmental Protection Agency; 2014.

11. Environmental Protection Agency (EPA). Volatile organic compounds' impact on indoor air quality [Internet]. 2017 [cited 2018 July 24]. Available from: https://www.epa. gov/indoor-air-quality-iaq/volatile-organic-compounds-impact-indoor-air-quality.

12. Iluțiu-Varvara D, Brânduşan L, Pică E. Researches
13. regarding the air pollution with sulfur dioxide (SO2) to the steelmaking. Advanced Engineering Forum 2013;8-9:115-26.

14. Iluţiu-Varvara D, Mârza C, Aciu C, Hădărean A, Domniţa F, Sas-Boca I, Mihu A. An assessment of pollution with volatile organic compounds in the electric arc furnaces. Procedia Technology 2016;22:45-6.

15. Kirschen M, Voj L, Pfeifer H. NOx emission from electric arc furnace in steel industry: Contribution from electric arc and co-combustion reactions. Clean Technologies and Environmental Policy 2005;7(4):236-44.

16. Kundak M, Lazic L, Crnko J. CO2 Emissions in the steel industry. Metalurgija 2009;48(3):193-7

17. Liu K, Yeh K, Hung M, Chen C, Shen Y. Health risk analysis of indoor air pollution. International Journal of Environmental Science and Development 2015;6(6): 464-8.

18. New Jersey Department of Health and Senior Services (NJDHSS). Hazardous Substances Fact Sheet. New Jersey, USA: New Jersey Department of Health and Senior Services; 2000.

19. Odabasi M, Bayram A, Elbir T, Seyfioglu R, Dumanoglu, Bozlaker A, Demircioglu H, Altiok H, Yatkin S, Cetin B. Electric arc furnaces for steel-making: Hot spots for persistent organic pollutants. Environmental Science and Technology 2009;43(14):5205-11.

20. Office of Environmental Health Hazard Assessment (OEHHA). OEHHA acute, 8-hour and chronic reference exposure level (REL) summary [Internet]. 2015 [cited 2019 April 1]. Available from: https://oehha.ca.gov/ air/general-info/oehha-acute-8-hour-and-chronic-reference-exposure-level-rel-summary.

21. Ontario Ministry of labour (OMOL). Current occupational exposure limits for ontario workplaces required
22. under regulation 833 [Internet]. 2014 [cited 2018 July 22]. Available from: https://www.labour.gov.on.ca/ english /hs/pubs/oel_table.php.

23. Rafiei M, Gadgil AS, Ghole VS, Gore SD, Jaafarzadeh N, Mirkazemi R. Assessment of air pollution and its effects on the health status of the workers in beam rolling mills factory (Iran National Steel Industrial Group) from Ahvaz-Iran. The Indian Journal of Occupational and Environmental Medicine 2009;13(1): 20-2.

24. Valenti C, Pozzi P, Busia A, Mazza R, Bossi P, Marco C, Rupretch A, Borgini A, Boffi R. Respiratory illness and air pollution from the steel industry: The case of Piquiá de Baixo, Brazil. Multidisciplinary Respiratory Medicine 2016;11(41):1-7.

25. World Healt Organization (WHO). Air Quality Guidelines for Europe. 2nd ed. Copenhagen, Denmark: WHO Regional Publications; 2000.

26. World Healt Organization (WHO). Air Quality Guidelines for Particulate Matter, Ozone, Nitrogen Dioxide and Sulfur Dioxide. Geneva, Switzerland: World Health Organization Press; 2005.

27. World Health Organization (WHO). Health Risks of Ozone From Long-Range Transboundary Air Pollution. Copenhagen, Denmark: WHO Regional Publications; 2010.

28. World steel Association (WSA). Steel Statistical Yearbook. Brussels, Belgium: World Steel Association; 2017.

29. World steel Association (WSA). World steel in figures 2018. Brussels, Belgium: World Steel Association; 2018.

30. Wu X, Zhao L, Zhang Y, Zheng C, Gao X, Cen K. Primary air pollutant emissions and future prediction of iron and steel industry in china. Aerosol and Air Quality Research 2015;15:1422-32.