Intrapartum Amniotic Fluid Index as Predictor of Perinatal Outcome in High Risk Pregnancy

Main Article Content

Apichart Chittacharoen
Cherdpong Chinnawuth
Pratak O-Prasertsawat

Abstract

Objective: To determine the diagnostic value of amniotic fluid index in the early intrapartum period for predicting of perinatal outcome in high risk pregnancy.


Methods: Four hundred and fifty high risk pregnant women of at least 34 weeks gestation were recruited at Department of Obstetrics and Gynaecology, Ramathibodi Hospital, Mahidol University, Bangkok, Thailand. The measurement of four-quadrant amniotic fluid index was performed by ultrasonography in the early intrapartum period. The amniotic fluid index £ 5 cm was the cutoff point for the predicting of poor perinatal outcome. The result of amniotic fluid index was compared to the perinatal outcome using sensitivity, specificity, negative predictive value, positive predictive value and accuracy.


Results: Among 450 high risk pregnancies, 92 cases (20.44%) were amniotic fluid index £ 5 cm, and 358 cases (79.56%) were amniotic fluid index > 5 cm. The incidence of poor perinatal outcome was 16.67%. An intrapartum amniotic fluid index of ≤ 5 cm, in comparison with > 5 cm, is associated with an increased risk of poor perinatal outcome (P < 0.05). The sensitivity, specificity, positive and negative predictive values and accuracy of four-quadrant amniotic fluid index ≤ 5 cm for predicting perinatal outcome were 72%, 89.86%, 58.69%, 94.13%, and 86.88%, respectively.


Conclusion: An intrapartum amniotic fluid index of ≤ 5 cm is associated with a significantly increased risk of poor perinatal outcome. The amniotic fluid index measurement is an effective diagnostic test to identify fetus at risk in the intrapartum period of the high risk pregnancy.

Article Details

How to Cite
1.
Chittacharoen A, Chinnawuth C, O-Prasertsawat P. Intrapartum Amniotic Fluid Index as Predictor of Perinatal Outcome in High Risk Pregnancy. Rama Med J [Internet]. 2012 Mar. 30 [cited 2024 Mar. 29];35(1):14-8. Available from: https://he02.tci-thaijo.org/index.php/ramajournal/article/view/117695
Section
Original Articles

References

Ingemarsson I, Arulkumaran S, Ingemarsson E, Tambyraja RL, Ratnam SS. Admission test: a screening test for fetal distress in labor. Obstet Gynecol. 1986;68(6):800-6.

Sarno AP, Ahn MO, Phelan JP, Paul RH. Fetal acoustic stimulation in the early intrapartum period as a predictor of subsequent fetal condition. Am J Obstet Gynecol. 1990;162(3):762-7. doi:10.1016/0002-9378(90)91004-v.

Malcus P, Gudmundsson S, Marsál K, Kwok HH, Vengadasalam D, Ratnam SS. Umbilical artery Doppler velocimetry as a labor admission test. Obstet Gynecol. 1991;77(1):10-6.

Sarno AP Jr, Ahn MO, Brar HS, Phelan JP, Platt LD. Intrapartum Doppler velocimetry, amniotic fluid volume, and fetal heart rate as predictors of subsequent fetal distress. I. An initial report. Am J Obstet Gynecol. 1989;161(6 Pt 1):1508-14. doi:10.1016/0002-9378(89)90914-9.

Chauhan SP, Magann EF, Scott JR, Scardo JA, Hendrix NW, Martin JN Jr. Cesarean delivery for fetal distress: rate and risk factors. Obstet Gynecol Surv. 200358(5):337-50. doi:10.1097/01.OGX.0000066802.19138.AE.

Rutherford SE, Phelan JP, Smith CV, Jacobs N. The four-quadrant assessment of amniotic fluid volume: an adjunct to antepartum fetal heart rate testing. Obstet Gynecol. 1987;70(3 Pt 1):353-6.

Baron C, Morgan MA, Garite TJ. The impact of amniotic fluid volume assessed intrapartum on perinatal outcome. Am J Obstet Gynecol. 1995;173(1):167-74. doi:10.1016/0002-9378(95)90185-x.

Chauhan SP, Cowan BD, Magann EF, Roberts WE, Morrison JC, Martin JN Jr. Intrapartum amniotic fluid index. A poor diagnostic test for adverse perinatal outcome. J Reprod Med. 1996;41(11):860-6.

Magann EF, Chauhan SP, Kinsella MJ, McNamara MF, Whitworth NS, Morrison JC. Antenatal testing among 1001 patients at high risk: the role of ultrasonographic estimate of amniotic fluid volume. Am J Obstet Gynecol. 1999;180(6 Pt 1):1330-6. doi:10.1016/s0002-9378(99)70015-3.

Chauhan SP, Washburne JF, Magann EF, Perry KG Jr, Martin JN Jr, Morrison JC. A randomized study to assess the efficacy of the amniotic fluid index as a fetal admission test. Obstet Gynecol. 1995;86(1):9-13. doi:10.1016/0029-7844(95)00110-D.

Williams K, Wittmann BK. The sensitivity and specificity of subjective and a semi-quantitative technique of amniotic fluid volume assessment in predicting intrapartum morbidity. Ultrasound Obstet Gynecol. 1993;3(3):180-4. doi:10.1046/j.1469-0705.1993.03030180.x.

Dildy GA 3rd, Lira N, Moise KJ Jr, Riddle GD, Deter RL. Amniotic fluid volume assessment: comparison of ultrasonographic estimates versus direct measurements with a dye-dilution technique in human pregnancy. Am J Obstet Gynecol. 1992;167(4 Pt 1):986-94. doi:10.1016/s0002-9378(12)80025-1.

Nabhan AF, Abdelmoula YA. Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome. Cochrane Database Syst Rev. 2008;(3):CD006593. doi:10.1002/14651858.CD006593.pub2.

Chauhan SP, Doherty DD, Magann EF, Cahanding F, Moreno F, Klausen JH. Amniotic fluid index vs single deepest pocket technique during modified biophysical profile: a randomized clinical trial. Am J Obstet Gynecol. 2004;191(2):661-7. doi:10.1016/j.ajog.2004.06.078.

Kawasaki N, Nishimura H, Yoshimura T, Okamura H. A diminished intrapartum amniotic fluid index is a predictive marker of possible adverse neonatal outcome when associated with prolonged labor. Gynecol Obstet Invest. 2002;53(1):1-5. doi:10.1159/000049402.